Home|News|Literature|Journal|Instruction|Forum|Member|Introduction

Chinese  Old version

By    In    Search 

  HomeContents of Chinese Journal of Mechanical Engineering 1991 No.5INVESTIGATION REPORT ON PERMISSIBLE VALUE OF ANVIL-BLOCK AMPLITUDE OF VIBRATION ISOLATION FORGING HAMMER
INVESTIGATION REPORT ON PERMISSIBLE VALUE

OF ANVIL-BLOCK AMPLITUDE OF VIBRATION

ISOLATION FORGING HAMMER

 

Yang Guotai  Jie Xiaoping  He Chenghong

(Jiangxi Polytechnic University)

 

Abstract: This article collects pratical data, domestic and international, on anvil-block amplitude of under-anvil vibration isolation forging hammer. It examines the working situation of under-anvil vibration isolation hammers in our country, and makes brief analysis on the effects caused by under-anvil vibration isolation on the production operation, the striking efficiency and by safty of equipment. It has been ascertained in practice and theory that when the anvil-block amplitude of forging hammer is amplified to 10~20mm, the production operation and the striking efficiency are not effected, a good vibration isolation effect can be obtained as well.
Key words: 隔振 振幅 允许值

Received 199009, received in revised form 199101

 

Open or Download Full Text of this Paper (PDF File)
 
  About us-Contact us-Site map-Advertisement service-Cooperation-Legal statement  

Address: 22 Baiwanzhuang Dajie, Beijing 100037 China    Tel: 8610-88379907    Fax: 8610-68994557

E-mail: cjme@mail.machineinfo.gov.cn  http: //www.cjmenet.com
©2006 Editorial Office of CJME. All Right Reserved