  HomeContents of Chinese Journal of Mechanical Engineering 2003 No.3RESEARCH ON THE EQUATION VANE CURVE UNDER NON-SEPARATION CONDITION CENTRIFUGAL PUMP
RESEARCH ON THE EQUATION VANE CURVE UNDER NON-SEPARATION CONDITION CENTRIFUGAL PUMP

 

Zhu Yucai  Liang Bing  Zhang Yongli
Xue Qiang  Su Ronghua

(Liaoning Technical University)

 

Abstract: According to the analysis on the boundary layer separation condition, parameter equation of vane curve for centrifugal pump is established. It is emphasized that the effect of boundary layer flow should not be neglected except for paying attention to the choice of parameters of inlet and outlet of vane in the design of centrifugal pumps. The choice of vane curve should satisfy the conditions of boundary layer non-separation and theoretical distance head by Eular equation—the basic equation of pumps. 

Key words: Centrifugal pump  Boundary layer separation     Equation of vane curve

CLC No: TD313

Received 20011231, received in revised form 20020925

 
Open or Download Full Text of this Paper (PDF File)
 