Abstract: This research made use of system of PIV (Particle image
velocimetry) that advanced measuring technique of fluid field to perform
exact highly measurement in the case of not interfering with fluid
field. Namely, it use optical astigmatism of the particle in the fluid
to record the site of particle at different time. Accordingly, it will
require the replacement of particles and measure the absolute
velocimetry of water in the centrifugal impeller passage and volute,
software is used to process the data and the blade-to-blade distribution
of the total relative velocities from suction to pressure side is
abtained in the centrifugal impeller passage. It provides reliable
theory basis for design of centrifugal pump.
Key words: System of PIV Measuring of fluid Centrifugal pump
CLC No: TH311
四川省教育厅重点资助项目(0224954).
Received 20041111, received in revised form 20050430
|