  HomeContents of Chinese Journal of Mechanical Engineering 2005 No.11EXPERIMENTAL ANALYSIS ON SEPARATION POINT MOVING OF BOUNDARY LAYER IN CENTRIFUGAL SLURRY PUMPS

EXPERIMENTAL ANALYSIS ON SEPARATION POINT MOVING OF BOUNDARY LAYER IN CENTRIFUGAL

SLURRY PUMPS

 

Zhu Yucai

(Traffic Institute, Ludong University, Yantai 264025)

Zhang Mengtao   Zhang Yongli

(Department of Mechanics and Engineering Sciences , Liaoning Technical University, Fuxin 123000)

Wu Yulin

(Department of Thermal Engineering, Tsinghua University, Beijing 100084)

 

Abstract: The boundary layer control equation and the reference point method of separation position moving on pressure surface of centrifugal slurry pumps are given out. By analysis on the results of separation moving test, it is indicated that the position of separation point may move with position coordinate of reference separation point, and the varying of vane shape is a major reason of the position moving of reference separation point. Having the aid of position coordinate of reference separation point, the point can be moved to outlet of vane by changing coefficient of vane shape. If the reference separation point approaches the outlet, the test results are satisfactory, which state that the practical position of boundary layer separation point will be close to the outlet.

Key words: Centrifugal slurry pumps  Separation point moving of boundary layer  Test analysis  Reference separation point

CLC No: TH38

Received 20050110, received in revised form 20050512

 
Open or Download Full Text of this Paper (PDF File)
 