  HomeContents of Chinese Journal of Mechanical Engineering 2005 No.4MACHINE FAULT DIAGNOSTICS BASED ON WIGNER-VILLE HIGH-ORDER SPECTRA

MACHINE FAULT DIAGNOSTICS BASED ON

WIGNER-VILLE HIGH-ORDER SPECTRA

 

Li Zhinong  He Yongyong  Chu Fulei

(Department of Precision Instruments and Mechanology, Tsinghua University, Beijing 100084)

 

Abstract: The Wigner higherorder moment spectra (WHOS), which are the extensions of the Wigner-Ville distribution (WVD) to higher-order moment spectra domains, can describe the higher-order moment spectral characteristics from the time domain and the frequency domain simultaneously. WHOS is a powerful tool for time-varying non-gauss analysis. WHOS to the machine fault diagnostics has been introduced, and how to remove cross-terms and suppress the gauss noise is stuelied. The simulation and experiment results show that the method is very effect- tive. Some valuable conclusions are obtained.

Key words: Wigner higher order moment spectra (WHOS)  Fault diagnostics  Time-frequency analysis

CLC No: TH165.3  TN911.7  TP206.3

中国博士后基金(20040350061)、国家自然科学基金(50105007)、国家杰出青年科学基金(50425516)和教育部“跨世纪优秀人才培养计划”基金资助项目. Received 20040715, received in revised form 20041214

  

Open or Download Full Text of this Paper (PDF File)
 