RUNNING
CHARACTERISTICS OF ADSORPTION COOLING TUBE AIR-CONDITIONER POWERED BY
WASTE HEAT OF ENGINEERING TRUCKS
WU
Weidong ZHANG Hua
(College of Power Engineering,
University of Shanghai for Science & Technology, Shanghai 200093)
|
|
Abstract: An
adsorption cooling tube knockdown air conditioning system powered by
waste heat of engineering trucks is designed and manufactured. The
relevant theoretical models and performance analysis indexes are
presented. Then running performance experiments and relevant analysis
for the air conditioning system are carried out. Under the conditions of
a certain outside environment and 30 min of half cycle time, the maximum
refrigerating temperature fall extent of cooled air is 13.0 ℃, the
maximum cooling power is 1.10 kW, the mean cooling power of the system
is 842 W, the coefficient of performance e c is 0.168, the specific
cooling power Ps is 88.2 W/kg, when air is used as the cooling medium
for the adsorber of air conditioner. The maximum refrigerating
temperature fall extent of cooled air is increased to 14.0 ℃, the
maximum cooling power, the mean cooling power of the system, e c and Ps
are up to 1.21 kW, 926 W, 0.177 and 97.0 W/kg, respectively, when an
improved cooling way for the adsorber of air conditioner is used. The
conclusions can be drawn that the increased extent of e c is about 5.4%,
and the increased extent of the maximum cooling power, the mean cooling
power or Ps is near 10% respectively.
Key words: Adsorption
refrigeration Cooling tube Zeolite/water Engineering trucks
Air-conditioner
CLC No: TB6
上海市重点学科建设项目(T0503), 上海市教委自然科学一般项目和中国留学回国人员科研启动基金资助项目.
Received 20051119, received in revised form
20060410
|