  HomeContents of Chinese Journal of Mechanical Engineering (English Edition),2004 No.2STUDY ON LOCATION OF HOT SPOT AT TUBE WALL FOR FIRED CYLINDRICAL FURNACE COMBUSTION

Wang Taiyong

 

Lu Shizhong

College of Mechanical Engineering,

Tianjin University,

Tianjin 300072, China

 

Xü Zhixue

Tianjin Petrochemical Crop.,

Tianjin 300271, China

 

 

STUDY ON LOCATION OF HOT SPOT AT TUBE WALL FOR FIRED CYLINDRICAL FURNACE COMBUSTION*

 

Abstract: Based on the analysis of heat radiation intensity from flame, a new mathematical model of the tube-wall temperature of heated tubes is developed by taking down-fired, upright-tube cylindrical furnace for example. The proposed mathematical model can be employed to indicate both the position and size of the hot spot at fire-facing wall of heated tube of combustion chamber, and is characteristic of simplicity and efficiency. If coupled with thermoelectric couple or infrared viewer, the presented location method of combustion hot spot can offer engineers very valuable proposal to keep furnace running more safely. The same is true for any other type of tubular furnaces.

Key words: Cylindrical furnace  Combustion  Heat radiation intensity  Tube-wall temperature Hot spot

 


* This project is supported by National Natural Science Foundation of China (No.50175081). Received April 7, 2003; received in revised form February 3, 2004; accepted February 24, 2004

 

Open or Download Full Text of this Paper (PDF File)